Guides / Setup
What Should an Electronics Assembly Plant Look For in a Rented Building?
November 21, 2026
An electronics assembly plant can run in a standard ready-built factory, as long as the building gives you four things: stable power with spare capacity, a floor that takes an anti-static finish, enough air conditioning capacity for a controlled climate and clean dock access for sensitive goods. Weight is rarely the problem. Power and climate usually are.
This guide lists what to check when you rent a building for SMT, box-build or final assembly in southern Vietnam, and what to leave to fit-out.
The specs that matter
| Spec | Why electronics needs it | What to ask the owner |
|---|---|---|
| Power in kVA | Lines, test equipment and air conditioning run all day | Transformer size, whether it is dedicated, how long an upgrade takes |
| Power quality | Voltage dips can stop a reflow oven or damage boards | Is the park substation stable? Any history of outages? |
| Floor surface | ESD coating or ESD tiles need a flat, dry slab | Slab age, cracks, moisture, flatness |
| Clear height | Ceiling, ducting, lighting and a false ceiling take height | Clear height under the beam |
| Roof | Exhaust ducts from reflow and wave soldering go through it | Roof type, load rating, leak history |
| Docks | Goods in and out need to stay dry and clean | Covered docks, levellers, truck turning space |
| Fire approval | Plastics, packaging and batteries raise the fire load | Approved use of the building and sprinkler status |
Power: size it and test it
Electronics plants run long hours and often three shifts. The load is steady and the cost of a trip is high, so power gets more attention than in most other trades.
Start with the connected load from your equipment makers: SMT lines, reflow ovens, test benches, compressors and chillers. Add the air conditioning separately, because in a tropical climate it often takes a large share of the total. Then compare the sum with the transformer in the unit. Our guide to factory power supply in kVA explains how to read the plate and what dedicated versus shared means.
Two more points are specific to electronics:
- Backup. Ask what happens in an outage. Many plants add a UPS for the lines and a generator for the rest. Check there is space outside the building and that the lease allows it.
- Earthing. Good earthing matters for ESD control and for test equipment. Ask whether the building has a documented earthing system, and plan on measuring it.
Floor: flat, dry and ready for ESD
ESD floors are usually epoxy coatings or vinyl tiles with a conductive layer. They need a clean, flat and dry slab. Check for:
- Cracks, joints that move and patched areas
- Rising damp or water marks after rain
- Floor flatness where your lines will sit
SMT and assembly equipment is lighter than machining or press equipment, so a standard industrial slab is often enough. Check the heavy items one by one: reflow ovens, wave soldering machines, racking for reels and finished goods, and any forklift traffic. Our guide to floor load capacity shows how to read point loads.
Climate: temperature, humidity and clean air
Most electronics work asks for a narrow temperature and humidity band. The values come from your equipment makers and your customers’ standards, not from the landlord. What the building must offer is the capacity to reach them.
- Insulation. A bare metal roof heats the hall and raises the HVAC load. Insulated roof panels or a ceiling reduce the cost of cooling every month. See roof insulation and heat for what to look for.
- Sealed envelope. Gaps at doors, dock edges and wall joints let in humid air. Humidity control is hard when the building leaks.
- Plant space. Chillers, air handling units and ducting need outdoor space and a path from the plant to the hall. Ask where they can go.
- Moisture-sensitive parts. Dry cabinets or a dry store for components are a fit-out item, but they need a small, well-sealed room.
If you need a certified cleanroom, for camera modules, displays or some semiconductor back-end work, the base building matters more. Read what a cleanroom-ready factory needs before you shortlist.
Utilities that surprise first-time tenants
Electronics plants need more than power and water. Check what exists and what you must build:
- Compressed air, and clean dry air where your process asks for it
- Nitrogen, from a generator or from bottles, if you run nitrogen reflow
- Exhaust ducting from reflow and wave soldering
- Cable trays, raised floor or ceiling space for network and test cables
- Fast, redundant internet. Your ERP and customer systems depend on it
Most of this is tenant fit-out. The question for the owner is whether the structure, roof and utilities allow it, and who pays for the connections.
Looking for a factory now? Send my requirements
Docks and logistics
Boards, modules and finished products are sensitive to rain, dust and shock. Prefer covered docks with levellers, so trucks and containers load without exposure to weather. Check the turning space for container trucks and the distance to the port or airport that your shipments use. Many electronics exporters ship by air as well as by sea, so check the road time to Tan Son Nhat airport as well as to the ports.
Fire safety and the fire load
Plastics, foam, cartons and batteries raise the fire load of an electronics plant. The building must have fire prevention approval for a use that covers your process. A warehouse approval may not cover a factory with soldering lines. Ask to see the approval and the acceptance record, and ask the park management board what is needed if your use differs. Our guide to fire safety approval covers what to ask for.
Typical order of work
- Write the brief: area, kVA, clear height, climate needs, headcount, move-in date.
- Shortlist units where power and height already fit.
- Visit with your engineers, not only your managers. Bring the equipment drawings.
- Agree in the lease who upgrades power, who pays for HVAC connections and how long the rent-free fit-out period lasts.
- Fit out and qualify the lines before you plan first shipment.
Fit-out for electronics takes longer than for most assembly trades because of the climate, floor and utilities. Plan the schedule with your suppliers, not with the landlord’s estimate.
Staff, audits and customer rules
Electronics customers often audit the building as well as the process. They look at ESD control, material handling, traceability, fire safety and working conditions. Ask your customers early which audits apply and when. The building should leave room for gowning or ESD entry points, a clean material path, a controlled store for components and a separate area for scrap and rework.
Headcount matters too. Assembly lines can employ hundreds of workers per shift, so check toilets, a canteen, parking and the road to the park gate at shift change. Our guide to worker facilities lists what to count.
Questions to ask on the first visit
- Can I see the single-line diagram of the electrical system and the last outage record?
- Which part of the roof can take exhaust ducts, and who approves the cuts?
- Where can the chillers and air handling units go?
- What is the slab like under the area where the lines will sit?
- Does the fire approval cover assembly with plastics and packaging stock?
- How long did the last tenant take to fit out a similar plant?
Get a shortlist
Tell us your area, power, climate needs and move-in date, and we will check units against them. Send your requirements and we reply within 24 business hours with a shortlist of up to 5 factories we have checked on site.
Frequently asked questions
Does an SMT line need a special building?
Not a special building, but a controlled one. The shell can be a standard ready-built unit. What matters is stable power, a floor that can take an ESD coating, air conditioning capacity and a roof that can carry exhaust ducts from reflow ovens.
Do I need a cleanroom for electronics assembly?
Most SMT and box-build work does not need a certified cleanroom. It needs clean, temperature-controlled and humidity-controlled areas. Camera modules, displays and some semiconductor back-end work do need a cleanroom, which is a larger fit-out.
How much power does an electronics plant need?
It depends on the number of lines and on air conditioning, which often takes a large share of the load. Ask your equipment suppliers for the connected load, add the HVAC and compare the total with the transformer size of the unit.
Is one floor enough or do I need a mezzanine?
Many plants run on one floor. A mezzanine for offices, storage or engineering is common, but it can need a construction permit and a fire safety review, so confirm this before you plan it.
Looking for a factory now?
Send your requirements. We reply within 24 business hours and shortlist up to 5 checked factories. No fee for tenants.