Most ready-built factories in southern Vietnam are cooled by the building itself, not by machines: roof vents let hot air out, openings in the walls let air in, and ceiling fans keep it moving. Air conditioning is rare in production halls and costly to run. Before you lease, check how the building lets heat out, then decide what you must add for your process and your workers.
Heat in the hall is not only a comfort matter. It affects output, quality, machine life and staff turnover. In a tropical climate it is worth designing for from the start.
Where the heat comes from
| Source | Examples |
|---|---|
| Sun on the roof | Metal sheeting without insulation |
| Process heat | Ovens, moulding machines, welding, dryers, compressors |
| People | Large crews at close spacing |
| Humidity | High in the rainy season, makes heat harder to bear |
Reduce the source first. A well-insulated roof removes much of the first source. Our roof guide shows how to check it. Then plan how to remove the heat that remains.
Natural ventilation: the base
Hot air rises. A building with air entering low and leaving high will move air without power. Look for:
- Ridge ventilators along the top of the roof, or turbine vents, that let hot air escape.
- Wall louvres or openings at a low level for fresh air to come in.
- Skylight openings that can open.
- Roller doors and dock doors that can stay open during hot hours.
Check that the vents are open and not blocked with dust, paint or birds’ nests. Check that the openings on both sides of the building line up, so air can flow across. A hall closed at the sides and open at the ridge will not draw air.
Mechanical options
Wall and roof exhaust fans
Fans pull hot air out and draw fresh air in. They need electricity and regular cleaning. Fix the number and size by the volume of the hall and the heat load. A supplier or ventilation engineer can calculate air changes per hour for your process.
HVLS fans
Large, slow ceiling fans move a lot of air across a wide area. They do not cool the air, but moving air helps sweat evaporate, so workers feel cooler. They suit warehouses and assembly areas. Check the clear height and the roof structure, since each fan hangs from the steel frame. Our clear height guide explains what you need.
Evaporative cooling pads
These pass air through wet pads. The evaporation cools it. They work well in hot, dry conditions and use less power than air conditioning. In humid weather they work less well, and they raise the humidity in the hall. This can harm products, paper, electronics and metals that rust. They also need clean water and regular maintenance.
Air conditioning
Chilled or split-system air conditioning gives full control of temperature and humidity. It is also the most expensive to buy and run. Use it where the process needs it, such as electronics assembly, clean areas, labs, offices, control rooms and inspection areas, and not for the whole hall unless required.
Spot cooling
Fans or cooling points aimed at workstations bring relief to the people who need it. They are cheap, flexible and easy to move.
Process-specific needs
- Electronics and precision work. Need steady temperature and humidity, and often an enclosed area with air conditioning. See our guide to electronics factories.
- Garment and textile. Large crews and many sewing machines raise heat, so airflow and dust control matter. See garment factories.
- Welding, painting and plating. Need fume extraction and fresh air under rules that your safety adviser can explain. Check with the landlord and the park on what is allowed.
- Food. Needs hygiene controls that can conflict with open vents. Plan the design early.
Workers’ comfort and rules
Workplace conditions in Vietnam are covered by labour and occupational health rules, including limits for temperature, humidity and air quality in workplaces. The details depend on your work. Ask a local safety adviser which standards apply to you, and ask the landlord for any past inspection results. Comfort also affects hiring: workers prefer a cooler hall and may choose a neighbour factory that offers it.
Looking for a factory now? Send my requirements
Energy and cost
Fans cost a fraction of air conditioning. As a rough rule, put cooling on the part of the plant that needs it, not the whole building. Ask your supplier for the installed power in kW, then use the electricity cost guide to estimate the bill. If you add a lot of cooling, check the transformer too, as shown in the power supply guide.
Questions for the landlord
- What ventilation does the building have today, and does it all work?
- Can I add roof or wall vents, fans or cooling equipment, and who approves it?
- Can I fix equipment to the roof structure or the columns?
- Are there limits on noise, exhaust or water use from the park?
- Is there existing air conditioning in the offices, and who maintains it?
Put approvals in the lease and in a side letter that lists the works you plan.
A simple way to choose
Start from the process, then the people, then the budget.
- List the heat sources and where they sit. A line of ovens in one corner needs local extraction, not whole-hall cooling.
- Decide the limits. Does the product need a set temperature or humidity? If not, aim for comfort for the workers.
- Use the building first. Open the vents, clear the louvres and add fans before you add cooling.
- Cool only what needs it. Put air conditioning on the zones that require it, with partitions around them.
- Check the electrical capacity. Cooling can add a large load to the transformer.
- Test in the hot season. Mid-year heat and humidity are the real test. A system that works in January may not in May.
Keep a record of hall temperature at several points during the first year. It tells you whether the changes are working and supports any request to the landlord for roof or vent repairs.
Dust, fumes and air quality
Cooling is only part of air quality. Machining mist, welding fumes, wood dust, solvent vapour and plastic odours all need capture at the source, with local exhaust and filters. General ventilation dilutes what remains. If your process produces any of these, tell the landlord early. The park may have limits on emissions to air, and the building may need roof penetrations for ducts and fans, which need approval.
Check also where exhaust goes. A duct that discharges next to a neighbour’s wall, a worker entrance or the air intake of another unit can lead to complaints. Ask the park management what its rules are on odour, noise and emissions before you design the system.
Get a shortlist
Tell us your process, your headcount and any temperature limits, and we will note the roof vents, openings and cooling in every unit we visit for you. Send your requirements and we reply within 24 business hours. Tenants pay nothing.
Frequently asked questions
Do ready-built factories in Vietnam have air conditioning?
Generally not in the production hall. Most are naturally ventilated with roof vents and wall openings, and offices are air-conditioned. Air conditioning or cooling for the hall is a tenant fit-out item unless the lease says otherwise.
Do evaporative cooling pads work in southern Vietnam?
They cool well on dry, hot days and less well when the air is already humid, as it often is in the rainy season. They also add humidity, which may not suit your process. Ask a supplier for a design based on local conditions.
What is an HVLS fan?
A high-volume low-speed fan is a large ceiling fan, often 3 to 7 m across, that moves a lot of air slowly. It makes workers feel cooler and is common in warehouses and assembly halls. It needs structure and height to fit.
Who pays for ventilation upgrades?
Usually the tenant, as part of fit-out. If the existing roof vents or openings are broken or missing, ask the landlord to restore them as part of the handover.
Looking for a factory now?
Send your requirements. We reply within 24 business hours and shortlist up to 5 checked factories. No fee for tenants.
Send my requirements